TH-GC Series Layer2 Elawulwa Ethernet Tshintsha 4xGigabit Combo(RJ45/SFP) 16×10/ 100/ 1000Base-T PoE/24×10/ 100/ 1000Base-T PoE
I-Gigabit Layer 2 eLawulayo i-PoE Switch yi-Green Energy-Saving PoE Switch ngokuzimeleyo. Ngomgangatho ophezulu kunye nesantya esiphezulu seNethiwekhi ye-IC kunye ne-PoE Chip ezinzile, izibuko ze-PoE zidibana ne-IEEE802.3af 15.4w kunye ne-IEEE802.3at 30w. Lo mzekelo unokubonelela ngoqhagamshelwano olungenamthungo lwe-10/ 100/ 1000M Ethernet, kwaye i-port yamandla ye-PoE inokubona ngokuzenzekelayo kwaye inike amandla izixhobo ezisebenza ngokuhambelana ne-IEEE802.3af/kwimigangatho. Izixhobo ze-Non-PoE zinikwe amandla ngenkani kwaye zihambisa kuphela idatha.
● Ukudlulisa idatha kwiikhamera zokucupha inethiwekhi
● Inkxaso IEEE802.3/ IEEE802.3i/IEEE802.3uIEEE802.3ab/IEEE802.3z, IEEE802.3af/at, store-and-forward
● Iyahambelana ne-IEEE802.3at (30W) kunye ne-IEEE802.3af (15.4w)
● I-Ethernet port isekela i-10/ 100/ 1000M i-adaptive kunye nemisebenzi ye-PoE
● Isalathisi sephaneli sibeka esweni ubume kunye nokunceda uhlalutyo lokusilela
● Ukuxhasa i-802.1x ukuqinisekiswa kwe-port, ukuxhasa ukuqinisekiswa kwe-AAA, ukuxhasa ukuqinisekiswa kwe-TACACS +; Izicwangciso zokuhlaselwa kwe-DOS, izicwangciso ze-ACL
● Inkxaso yeWEB, TELNET, CLI, SSH, SNMP, ulawulo lweRMON
● Ukuxhasa uLawulo lwaMandla e-PoE kunye ne-PoE Watchdog
● UkuKhuselwa koMbane: Imodi ePhambili ye-4KV, i-Differential Mode 2KV, i-ESD 15KV
P/N | Inkcazo |
TH-GC0416PM2-Z200W | ILayer2 eLawulwayo ye-Ethernet Switch 4x1Gigabit Combo( RJ45/SFP)I-16×10/ 100/ 1000Base-T PoE Port, iSibonelelo saNgaphakathi saMandla 52V/3.8A, 200w |
TH-GC0416PM2-Z300W | ILayer2 eLawulwayo ye-Ethernet Switch 4x1Gigabit Combo( RJ45/SFP)16×10/ 100/ 1000Base-T PoE Port , Ubonelelo lwangaphakathi lwaMandla 52V/5.76A, 300w |
TH-GC0424PM2-Z300W | ULayer2 oLawulwayo we-Ethernet Switch 4xGigabit Combo(RJ45/SFP)24×10/ 100/ 1000Base-T PoE Port, Ubonelelo lwaNgaphakathi lwaMandla 52V/5.76A, 300w |
TH-GC0424PM2-Z400W | ULayer2 oLawulwayo we-Ethernet Switch 4xGigabit Combo(RJ45/SFP)24×10/ 100/ 1000Base-T PoE Port, Ubonelelo lwaNgaphakathi lwaMandla 52V/7.69A, 400w |
I/O Interface | ||
Ungeniso lwamandla | Igalelo AC 110-240V, 50/60Hz | |
Izibuko ezizinzileyo | P/N | Izibuko ezizinzileyo |
TH-GC0416PM2-Z200w | 16 x 10/ 100/ 1000Mbps PoE Port | |
4 x 1000M Combo (RJ45/SFP) Port | ||
1 x RJ45 Console Port | ||
TH-GC0416PM2-Z300w | 16 x 10/ 100/ 1000Mbps PoE Port | |
4 x 1000M Combo (RJ45/SFP) Port | ||
1 x RJ45 Console Port | ||
TH-GC0424PM2-Z300w | 24 x 10/ 100/ 1000Mbps PoE Port | |
4 x 1000M Combo (RJ45/SFP) Port | ||
1 x RJ45 Console Port | ||
TH-GC0424PM2-Z400w | 24 x 10/ 100/ 1000Mbps PoE Port | |
4 x 1000M Combo (RJ45/SFP) Port | ||
1 x RJ45 Console Port | ||
Ukusebenza | ||
Ukutshintsha Umthamo | 56Gbps | |
Umsebenzi | 41.66Mpps | |
Packet Buffer | 4Mb | |
Inkumbulo yeFlash | 16MB | |
I-DDR SDRAM | 128MB | |
Idilesi ye-MAC | 8K | |
Isakhelo seJumbo | 9.6Kbytes | |
iiVLANs | 4096 | |
Imo Yokutshintshela | Gcina naphambili | |
MTBF | 100000 iiyure | |
Umgangatho | ||
Iprothokholi yenethiwekhi | IEEE 802.3: Ethernet MAC Protocol | |
IEEE 802.3i: 10BASE-T Ethernet | ||
IEEE 802.3u: 100BASE-TX Fast Ethernet | ||
IEEE 802.3ab: 1000BASE-T Gigabit Ethernet | ||
IEEE 802.3z: 1000BASE-X Gigabit Ethernet (ifiber optical) | ||
IEEE 802.3az: I-Enethernet eSebenza kakuhle | ||
IEEE 802.3ad: Indlela esemgangathweni yokwenza ukudibanisa ikhonkco | ||
IEEE 802.3x: Ulawulo lokuhamba | ||
IEEE 802.1ab: LLDP/LLDP-MED (IProtokholi yokuFumana iNqanaba loQhagamshelwano) | ||
IEEE 802.1p: ILayer ye-LAN QoS/CoS iProtocol yeProtocol ePhambili kwiTrafikhi (Multicast | ||
umsebenzi wokucoca) | ||
IEEE 802.1q: Ukusebenza kweBhulorho yeVLAN | ||
IEEE 802.1x: ULawulo lokuFikelela koMthengi/Iseva kunye neProtokholi yoQinisekiso | ||
IEEE 802.1d: STP; IEEE 802.1s: MSTP; IEEE 802.1w: RSTP | ||
Umgaqo wePoE | IEEE802.3af (15.4W); IEEE802.3at (30W) | |
Umgangatho woShishino | I-EMI: Icandelo le-FCC 15 CISPR (EN55032) iklasi A | |
EMS: EN61000-4-2 (ESD), EN61000-4-4 (EFT), EN61000-4-5 (Surge) | ||
Umothuko: IEC 60068-2-27 | ||
Ukuwa kwamahala: IEC 60068-2-32 | ||
Ukungcangcazela: IEC 60068-2-6 | ||
Uthungelwano oluPhakathi | 10Base-T: Ikati3, 4, 5 okanye ngaphezulu kwe-UTP(≤100m) | |
100Base-TX: Ikati5 okanye ngaphezulu kwe-UTP(≤100m) | ||
1000Base-TX: Ikati5 okanye ngaphezulu kwe-UTP(≤100m)Optical | ||
I-Multimode fiber: 1310nm, 2Km | ||
I-fiber yemodi enye: 1310nm, 20/40 Km; 1550nm, 60/80/100/120Km | ||
Ukhuseleko | ||
Isatifikethi soKhuseleko | CE/FCC/RoHS | |
Okusingqongileyo | ||
Indawo yokusebenza | Ubushushu bokusebenza: -20~55°C | |
Ubushushu boGcino: -40~85°C | ||
Ukufuma okusebenzayo: 10% ~ 90%,ukungaxinanisi | ||
Ubushushu boGcino: 5% ~ 90%,ukungaxinanisi | ||
Ubude bokusebenza: Ubuninzi beenyawo ze-10,000 | ||
Ubunzima bokugcina: Ubuninzi beenyawo ezili-10,000 | ||
Isalathiso | ||
Izalathisi ze-LED | PWR (ubonelelo lwamandla) | |
I-SYS (Inkqubo) | ||
1-24 iPoE & ACT (PoE) | ||
I-1-24 ikhonkco kunye ne-ACT (Ikhonkco kunye nesenzo) | ||
25-28 Ikhonkco (Ikhonkco) | ||
25-28 Umthetho (uMthetho) | ||
DIP Tshintshela | Lungisa kwakhona | |
Oomatshini | ||
Ubungakanani besakhiwo | Ubungakanani bemveliso (L * W * H): 440 * 284 * 44mm | |
Ubungakanani bePakethe (L * W * H): 495 * 350 * 103mm | ||
NW: 3.5kg | ||
GW: 4.25kg | ||
Ukupakisha Ulwazi | I-Carton MEAS: 592 * 510 * 375mm | |
Ukupakisha Ubuninzi: iiyunithi ezi-5 | ||
Ukupakisha ubunzima: 22.5KG | ||
Umaleko wesi-2 woMsebenzi weSoftwe | ||
Ulawulo lweZibuko | Yenza/Yenza Vala Isiqhagamshelanisi | |
Isantya, i-Duplex, i-MTU Setting | ||
Ulawulo lokuqukuqela | ||
UkuJonga ulwazi lwePort | ||
Isibuko sePort | Ixhasa zombini izibuko zokujonga isipili | |
Port Speed Limit | Ixhasa i-port-based input / output bandwidth management | |
Ukwahlulwa kweZibuko | Xhasa i-downlink port yodwa, kwaye inokunxibelelana ne-uplink port | |
Ukucinezelwa kweSiqhwithi | Ixhasa i-unicast engaziwayo, i-multicast, i-multicast engaziwayo, uhlobo losasazo loxinzelelo lwesaqhwithi | |
Uxinzelelo lwesaqhwithi olusekwe kulawulo lwe-bandwidth kunye nokucoca isiphango | ||
Udibaniso lonxulumano | Inkxaso yodibaniso lwemanyuwali olungagungqiyo | |
Inkxaso ye-LACP yokudibanisa okuguquguqukayo | ||
VLAN | Ukufikelela | |
Umboko | ||
Umhlanganiselwa | ||
I-port yenkxaso, iprotocol, ukwahlulahlula kwe-VLAN esekwe kwi-MAC | ||
Inkxaso ye-GVRP yokubhaliswa kweVLAN eguqukayo | ||
Ilizwi leVLAN | ||
IMAC | Ukuxhasa ukongezwa kwe-static, ukucima | |
Umda wokufunda idilesi ye-MAC | ||
Ukuxhasa ukusetwa kwexesha lokuguga eliguqukayo | ||
Umthi ojikelezayo | Inkxaso ye-STP enwebekayo yomthi umthetho | |
Ixhasa iProtocol ye-RSTP eNquba ngokukhawuleza yoMthi | ||
Ixhasa iProtokholi ye-MSTP eNgxamisekileyo yoMthi | ||
I-Multicast | Ukuxhasa ukongezwa kwe-static, ukucima | |
IGMP-snooping | ||
Inkxaso ye-MLD-Snooping | ||
Inkxaso ye-v1/2/3 eguquguqukayo yokubeka iliso kwi-multicast | ||
DDM | Inkxaso ye-SFP/SFP+DDM | |
Umsebenzi owandisiweyo | ||
ACL | Ngokusekwe kumthombo we-MAC, indawo yokufikela ye-MAC, uhlobo lweprotocol, umthombo we-IP, indawo ekuyiwa kuyo | |
IP, L4 izibuko | ||
QoS | Ngokusekelwe kuhlelo lwe-802.1p (COS). | |
Ngokusekwe kuhlelo lweDSCP | ||
Ulwahlulo olusekwe kumthombo we-IP, indawo yokufikela ye-IP, kunye nenombolo ye-port | ||
Inkxaso ye-SP, isicwangciso sokucwangcisa iWRR | ||
Inkxaso yesantya sokuhamba komda weCAR | ||
I-LLDP | Xhasa i-LLDP yekhonkco lokufumana iprotocol | |
Useto lomsebenzisi | Yongeza/cima abasebenzisi | |
Ngena | Ukungena komsebenzisi, ukusebenza, isimo, imicimbi | |
Anti-uhlaselo | DOS ukukhusela | |
Ixhasa ukhuseleko lwe-CPU kwaye unciphise izinga lokuthumela iipakethi ze-CPU | ||
Ukubophelela kwe-ARP (IP, MAC, PORT idibanisa) | ||
Isiqinisekiso | Inkxaso 802.1x port uqinisekiso | |
Ukuxhasa isatifikethi se-AAA | ||
Ukuxilongwa kwenethiwekhi | I-ping yenkxaso, i-telnet, umkhondo | |
Ulawulo lweNkqubo | Ukusetwa kwakhona kwesixhobo, ukusetwa kogcino/ukubuyisela, ukuphuculwa kolawulo, ukusetwa kwexesha, njl. | |
Umsebenzi wolawulo | ||
CLI | Inkxaso yolandelelwano lolawulo lomyalelo wezibuko lomyalelo | |
I-SSH | Inkxaso ye-SSHv1/2 yolawulo olukude | |
TELNET | Inkxaso yolawulo lwe-telnet olukude | |
WEBHU | Inkxaso yeLayer 2 useto, iLayer 2 kunye neLayer 3 monitor | |
I-SNMP | I-SNMP V1/V2/V3 | |
Umgibe wenkxaso: ColdStart, WarmStart, LinkDown, LinkUp | ||
RMON | Inkxaso ye-RMON v1 | |
PoE | Inkxaso yobonelelo lwamandla e-PoE | |
Eminye imisebenzi | Inkxaso ye-DHCP Snooping, Option82, i-DHCP Server | |
Ixhasa ubhaqo lwe-ARP eguqukayo | ||
Inkxaso yoqinisekiso lwe-TACACS+ | ||
Ukuxhasa isiqinisekiso seDNS | ||
Inkxaso kwizicwangciso zokhuseleko lwezibuko | ||
Inkxaso yeprotocol ye-MVR | ||
Inkxaso yokufumanisa umsebenzi weVCT | ||
Inkxaso yeprotocol ye-UDLD |