I-TH-G Series Layer2 eLawula i-Ethernet Switch 2xGigabit SFP, 8×10/100/1000Base-T 4xGigabit Combo (RJ45/SFP) 24×10/100/1000Base-T Port
Olu tshintsho luLawulwayo lwe-Gigabit Layer 2 luxhotyiswe nge-8(24)x ye-Gigabit Ethernet Ports kunye ne-2(4)x ye-Gigabit SFP Ports eziziqhelanisa ngokuzenzekelayo kwindlela epheleleyo okanye enesiqingatha se-duplex. Idilesi ye-MAC yokutshintsha itekhnoloji yokuzifundela itekhnoloji yenza ukuba ukuhanjiswa kwedatha kungabi nampazamo, ngelixa imowudi yayo yokugcina kunye nephambili ikhusela iipakethi ezonakalisiweyo ekukhukuliseni inethiwekhi. Ukongezelela, olu tshintsho lubonisa umsebenzi wokulawula ukuhamba onokuthi uthintele inani elikhulu ledatha ngokukhawuleza ukuba libe nefuthe kwinethiwekhi.
Umtshintshi ubonelela ngemisebenzi yolawulo lwenethiwekhi ephezulu njengenethiwekhi ye-ring, i-VLAN, i-cluster, i-QoS, ulawulo lwesantya, umfanekiso we-port, i-alarm yephutha, kunye nokuphuculwa kwe-intanethi ye-firmware. Isasazwe ngokubanzi kwiimeko zokufikelela kwi-Ethernet kumashishini amancinci ukuya kophakathi, iikhefi ze-intanethi, iihotele, izikolo, kunye nokunye. Ngeempawu zayo ezibanzi, olu tshintsho lubonelela ngokusebenza kwenethwekhi ethembekileyo kwaye lusebenzayo kwaye lunceda amashishini afezekise unxibelelwano olungenamthungo kunye nokudluliselwa kwedatha.
● Inkxaso IEEE802.3/ IEEE802.3u/ IEEE802.3ab/IEEE802.3z, ivenkile-kunye-phambili
● Imowudi yokulawula ukuhamba: i-duplex epheleleyo ithatha i-IEEE 802.3x eqhelekileyo, i-half-duplex ithatha umgangatho woxinzelelo lwangasemva
● I-port auto flip yenkxaso (Auto MDI/MDIX)
● Isalathisi sephaneli sibeka esweni ubume kunye nokunceda uhlalutyo lokusilela
● Inkxaso ye-802.1x yokuqinisekisa i-port, inkxaso ye-AAA yokuqinisekisa, inkxaso ye-TACACS + ukuqinisekiswa
● Inkxaso yeWEB, TELNET, CLI, SSH, SNMP, ulawulo lweRMON
● Ukukhuselwa koKhuseleko: Jikelele 4KV, Umahluko 2KV, ESD 8KV umoya, 6KV uqhagamshelwano
I/O Interface | ||
Ungeniso lwamandla | AC 100-240V, 50/60Hz | |
Izibuko ezizinzileyo | P/N | Izibuko ezizinzileyo |
TH-G0208M2-R | 8*10/ 100/ 1000Mbps Ethernet Port | |
2 * 1000Mbps SFP Port | ||
1*Console Port | ||
TH-G0424M2-Z | 24 x 10/ 100/ 1000Mbps Port | |
4 x 1000M Combo (RJ45/SFP) Port | ||
1 x RJ45 Console Port | ||
Ukusebenza | ||
Ububanzi | I-20Gbps (engathinteliyo)/56Gbps | |
Ireyithi yokuThuthukisa ipakethi | 14.88Mpps/41.66Mpps | |
Packet Buffer | 4M | |
Umthamo weMemori | 128MB | |
Umthamo weFlash | 16MB | |
Idilesi ye-MAC | 8K | |
iiVLANs | 4096 | |
Isakhelo seJumbo | 9.6Kbytes | |
Imo Yokutshintshela | Gcina naphambili | |
MTBF | 100000 iyure | |
Umgangatho | ||
Iprothokholi yenethiwekhi | IEEE802.3: 10Base-T | |
IEEE802.3u: 100Base-TX | ||
IEEE802.3ab : 1000Base-TX | ||
IEEE802.3z :1000Base- FX | ||
IEEE 802.3x: Ulawulo lokuhamba | ||
IEEE 802.1ab : LLDP/LLDP- MED (IProtokholi yokuFumana iNqanaba loQhagamshelwano) | ||
IEEE 802.1p: Ulwaleko lwe-LAN QoS/CoS iProtokholi yoMsebenzi weNdlela ePhambili (umsebenzi wokuhluza ii-Multicast) | ||
IEEE 802.1q: Ukusebenza kweBhulorho yeVLAN | ||
IEEE 802.1x: ULawulo lokuFikelela koMthengi/Iseva kunye neProtokholi yoQinisekiso | ||
IEEE 802.3ad : Indlela esemgangathweni yokwenza ukudibanisa ikhonkco | ||
IEEE 802.1d : STP | ||
IEEE 802.1s: MSTP | ||
IEEE 802.1w: RSTP | ||
Umgangatho woShishino | I-EMI: Icandelo le-FCC 15 CISPR (EN55032) iklasi A | |
I-EMS: EN61000-4-2 (ESD), | ||
EN61000-4-5 (Surge) | ||
Uthungelwano oluPhakathi | ||
10Base-T: Ikati3/4/5 okanye ngaphezulu kwe-UTP(≤100m) | ||
100Base-TX: Ikati5 okanye ngaphezulu kwe-UTP(≤100m) | ||
1000Base-TX: Ikati5 okanye ngaphezulu kwe-UTP (≤100m) | ||
Iimpawu ze-Optical | Imowudi emininzi: 850/ 1310nm (0-2KM) | |
Imowudi enye: 1310/ 1550/ 1490nm (0- 120KM) | ||
Izatifikethi | ||
Isatifikethi soKhuseleko | CE, FCC, RoHS | |
Okusingqongileyo | ||
Indawo yokusebenza | Ubushushu bokusebenza: – 10–50.C | |
Ubushushu boGcino: -40 ~ 70.C | ||
Ukufuma okuSebenzayo: 10% ~ 90%, ukungazinzi | ||
Ubushushu bokugcina: 5% ~ 90%, ayinciphisi | ||
Isalathiso | ||
Izalathisi ze-LED | PWR, SYS, Link, UMTHETHO | |
Oomatshini | ||
Ubungakanani besakhiwo | Ubungakanani boMveliso: 268 * 181 * 44mm | |
Ubungakanani bePakethe: 312 * 262 * 84mm | ||
Product Net-Ubunzima: 1.01KG | ||
Product Gross-Weight: 1.54KG | ||
/ | ||
Ubungakanani boMveliso (L * W * H) : 440 * 284 * 44mm | ||
Ubungakanani bePakethe (L*W*H): 495*350*103mm | ||
NW: 3.5kg | ||
GW: 4.25kg | ||
Ukupakisha Ulwazi | MEAS: 540 * 435 * 332mm | |
Ukupakisha Ubuninzi: 10PCS | ||
Ukupakisha ubunzima: 16.4KG | ||
/ | ||
I-Carton MEAS: 592 * 510 * 375mm | ||
Ukupakisha Ubuninzi: iiyunithi ezi-5 | ||
Ukupakisha ubunzima: 22.5KG | ||
Umaleko wesi-2 woMsebenzi weSoftwe | ||
Ulawulo lweZibuko | Yenza/ Khubaza i-Port | |
Isantya, i-Duplex, i-MTU Setting | ||
Ukuqukuqela- ulawulo | ||
UkuJonga ulwazi lwePort | ||
Isibuko sePort | Ixhasa zombini izibuko zokujonga isipili | |
Port Speed Limit | Ixhasa i-port-based input / output bandwidth yolawulo | |
Ukwahlulwa kweZibuko | Xhasa i-downlink port yodwa, kwaye inokunxibelelana ne-uplink port | |
Ukucinezelwa kweSiqhwithi | Ixhasa i-unicast engaziwayo, i-multicast, i-multicast engaziwayo, uhlobo losasazo loxinzelelo lwesaqhwithi | |
Uxinzelelo lwesaqhwithi olusekwe kulawulo lwe-bandwidth kunye nokucoca isiphango | ||
Udibaniso lonxulumano | Inkxaso yodibaniso lwemanyuwali olungagungqiyo | |
Inkxaso ye-LACP yokudibanisa okuguquguqukayo | ||
VLAN | Ukufikelela | |
I-TrunkHybrid | ||
I-port yenkxaso, iprotocol, ukwahlulahlula kwe-VLAN esekwe kwi-MAC | ||
Inkxaso ye-GVRP yokubhaliswa kweVLAN eguqukayo | ||
Ilizwi leVLAN | ||
IMAC | Ukuxhasa ukongezwa kwe-static, ukucima | |
Umda wokufunda idilesi ye-MAC | ||
Ukuxhasa ukusetwa kwexesha lokuguga eliguqukayo | ||
Umthi ojikelezayo | Inkxaso ye-STP enwebekayo yomthi umthetho | |
Ixhasa iProtocol ye-RSTP eNquba ngokukhawuleza yoMthi | ||
Ixhasa iProtokholi ye-MSTP eNgxamisekileyo yoMthi | ||
I-Multicast | Ukuxhasa ukongezwa kwe-static, ukucima | |
IGMP- ukukhangela | ||
Inkxaso ye-MLD- Snooping | ||
Inkxaso ye-v1/2/3 eguquguqukayo yokubeka iliso kwi-multicast | ||
DDM | Inkxaso ye-SFP/SFP+DDM | |
ACL | Ngokusekwe kumthombo we-MAC, indawo yokufikela ye-MAC, uhlobo lweprotocol, umthombo we-IP, indawo yokufikela ye-IP, izibuko le-L4 | |
Qos | Ngokusekelwe kuhlelo lwe-802.1p (COS). | |
Ngokusekwe kuhlelo lweDSCP | ||
Ulwahlulo olusekwe kumthombo we-IP, indawo yokufikela ye-IP, kunye nenombolo ye-port | ||
Inkxaso ye-SP, isicwangciso sokucwangcisa iWRR | ||
Inkxaso yesantya sokuhamba komda weCAR | ||
I-LLDP | Xhasa i-LLDP yekhonkco lokufumana iprotocol | |
Useto lomsebenzisi | Yongeza/cima abasebenzisi | |
Ngena | Ukungena komsebenzisi, ukusebenza, isimo, imicimbi | |
Anti- attack | DOS ukukhusela | |
Ukuxhasa ukukhuselwa kwe-CPU kunye nokunciphisa izinga lokuthumela iipakethi ze-cpu | ||
Ukubophelela kwe-ARP (IP, MAC, PORT idibanisa) | ||
Isiqinisekiso | Inkxaso 8 0 2. 1 x uqinisekiso lwezibuko | |
Ukuxhasa isatifikethi se-AAA | ||
Ukuxilongwa kwenethiwekhi | I-ping yenkxaso, i-telnet, umkhondo | |
Ulawulo lweNkqubo | Ukusetwa kwakhona kwesixhobo, ukusetwa kogcino/ukubuyisela, ukuphuculwa kolawulo, ukusetwa kwexesha, njl. | |
CLI | Inkxaso yolandelelwano lolawulo lomyalelo wezibuko lomyalelo | |
I-SSH | Inkxaso ye-SSHv1/2 yolawulo olukude | |
MACTELNET | Inkxaso yolawulo lwe-telnet olukude | |
WEBHU | Inkxaso yeLayer 2 useto, iLayer 2 kunye neLayer 3 monitor | |
I-LLDP | Xhasa i-LLDP yekhonkco lokufumana iprotocol | |
Useto lomsebenzisi | Yongeza/cima abasebenzisi | |
Ngena | Ukungena komsebenzisi, ukusebenza, isimo, imicimbi | |
Anti- attack | DOS ukukhusela | |
Ukuxhasa ukukhuselwa kwe-CPU kunye nokunciphisa izinga lokuthumela iipakethi ze-cpu | ||
Ukubophelela kwe-ARP (IP, MAC, PORT idibanisa) | ||
Isiqinisekiso | Inkxaso 8 0 2. 1 x uqinisekiso lwezibuko | |
Ukuxhasa isatifikethi se-AAA | ||
Ukuxilongwa kwenethiwekhi | I-ping yenkxaso, i-telnet, umkhondo | |
Ulawulo lweNkqubo | Ukusetwa kwakhona kwesixhobo, ukusetwa kogcino/ukubuyisela, ukuphuculwa kolawulo, ukusetwa kwexesha, njl. | |
CLI | Inkxaso yolandelelwano lolawulo lomyalelo wezibuko lomyalelo | |
I-SSH | Inkxaso ye-SSHv1/2 yolawulo olukude | |
TELNET | Inkxaso yolawulo lwe-telnet olukude | |
WEBHU | Inkxaso yeLayer 2 useto, iLayer 2 kunye neLayer 3 monitor | |
I-SNMP
| I-SNMP V1/V2/V3 | |
Umgibe wenkxaso: ColdStart, WarmStart, Link Down, Link Up | ||
RMON | Inkxaso ye-RMON v1 | |
Eminye imisebenzi | Inkxaso ye-DHCP Snooping, Option82 | |
Ixhasa ubhaqo lwe-ARP eguqukayo | ||
Inkxaso yoqinisekiso lwe-TACACS+ | ||
Ukuxhasa isiqinisekiso seDNS | ||
Inkxaso kwizicwangciso zokhuseleko lwezibuko | ||
Inkxaso yeprotocol ye-MVR |